1.
Gac. méd. Caracas ; 120(4): 281-285, oct.-dic. 2012. ilus, tab, graf
Article in Spanish | LILACS | ID: lil-661904

ABSTRACT

Los factores de riesgo en enfermedad arterial coronaria fueron evaluados en historias clínicas y estudios de pruebas de esfuerzos con el protocolo de Duke. Los índices de certeza se definen y utilizan comparándolos con el "el patrón de oro" la arteriografía coronaria. Se establece el valor diagnóstico de la tomagrafía axial computarizada, basándose en los índices de certeza. también se mencionan los estudios intracoronarios para evaluar la placa obstructiva


Risk factors in coronary artery disease were evaluated with the clinical history and the stress test with the Duke protocol. Probability indexes were defined and compared with the gold standard (coronary arteriogram). The diagnostic value of coronary angiotac was established with probability indexes. Intracoronary studies to diagnose vulnerable plaque are also mentioned


Subject(s)
Humans , Male , Female , Bayes Theorem , Coronary Artery Disease/diagnosis , Coronary Artery Disease , Tomography, Emission-Computed/methods , Diagnostic Techniques, Cardiovascular/instrumentation
2.
Dermatol. argent ; 18(1): 44-51, ene.-feb. 2012. graf, tab
Article in Spanish | LILACS | ID: lil-724297

ABSTRACT

Antecedentes. La psoriasis es una enfermedad inflamatoria crónica multisistémica que implica un riesgo cardiovascular aumentado, incluidos enfermedad coronaria, infarto de miocardio y muerte de causa cardiovascular, sobre todo en pacientes jóvenes y con psoriasis más graves. Esto se debe a una aterogénesis precoz y en ocasiones subclínica, que podría ser identificada de manera no invasiva mediante estudios vasculares de vasos periféricos. Objetivos. a) identificar la presencia de ateroesclerosis subclínica en pacientes con psoriasis; b) establecer su valor predictivo independientemente de otros factores de riesgo cardiovascular. Diseño. Estudio de cohorte, prospectivo, controlado. Métodos. Se incluyeron 175 pacientes consecutivos, un grupo con psoriasis (GP, n:35) y un grupo control (GC, n:140), a quienes se les efectuó estudios de identificación de placas de ateroesclerosis y de elasticidad arterial en vasos carotídeos extracraneales y femorales. Resultados. El score de Framingham en los pacientes de ambos grupos fue bajo (7 ± 2,3% vs. 5,7 ± 1,8%; GP vs. GC respectivamente; p = .003), mientras que el score de riesgo vascular determinado según la alteración de parámetros de ateroesclerosis subclínica evaluados fue mayor en el GP (2,9 ± 1,2 vs. 2,2 ± 0.08; p = .002). La rigidez de la pared arterial se halló significativamente incrementada en el GP (EIM 0,7 ± 0,2 vs. 0,63 ± 0,1 mm, p< 0.001), donde se observó una prevalencia mayor de placas ateroescleróticas (94% vs. 62,5%, p = .001) la mayoría de alta vulnerabilidad. Conclusiones. El uso de técnicas no invasivas que faciliten la detección precoz de pacientes psoriásicos con enfermedad subclínica de la pared arterial, permitiría evaluar correctamente el riesgo, que puede ser subestimado si sólo se realizan estudios clínicos de los factores de riesgoconvencionales.


Background. Psoriasis is a chronic multisystem inflammatory disease that involves an increasedcardiovascular risk as heart disease, myocardial infarction and cardiovascular death, especially inyounger patients and severe psoriasis. This is due to early atherogenesis, and sometimes to a subclinicalcourse, which could be identified by non invasive vascular studies of peripheral vessels.Objectives. a) Identify the presence of subclinical atherosclerosis in patients with psoriasis; b)Determine its predictive value independently of other cardiovascular risk factors.Design. Cohort, prospective, controlled trial. Methods. 175 consecutive patients were included, a Psoriatic Group (PG, n:35) and a Control Group(CG, n:140) where identified, and submited to studies for identification of atherosclerotic plaquesand arterial elasticity in extracranial carotids and femoral vessels.Results. The Framingham scores in patients of both groups was low (7 ± 2.3% vs. 5.7 ± 1.8%;GP vs. GC respectively, p = .003) while the vascular risk score, determined by the alteration ofsubclinical atherosclerosis parameters, was higher in the GP (2.9 ± 1.2 vs. 2.2 ± 0.08, p = .002).The arterial wall stiffness was found significantly increased in the GP (EIM 0.7 ± 0.2 vs 0.63 ± 0.1mm, p< 0.001), where a higher prevalence of atherosclerotic plaques (94% vs. 62.5%, p = .001),mostly of high vulnerability, was also observed.Conclusions. The use of non invasive techniques that facilitate early detection of psoriaticindividuals with subclinical arterial wall disease, would allow a proper assessment of risk whichmay be underestimates by only clinical assessment of conventional risk factors.


Subject(s)
Humans , Male , Adult , Female , Atherosclerosis/diagnosis , Atherosclerosis/etiology , Psoriasis/complications , Early Diagnosis , Early Medical Intervention , Cardiovascular Diseases/etiology , Risk Factors , Diagnostic Techniques, Cardiovascular/instrumentation
3.
Rev. bras. eng. biomed ; 25(2): 101-105, ago. 2009. ilus, tab
Article in Portuguese | LILACS | ID: lil-556120

ABSTRACT

Técnicas cirúrgicas, próteses e dispositivos implantáveis utilizados pela cardiologia estão em constante desenvolvimento. Alguns institutos de pesquisas e universidades desenvolvem simuladores hidrodinâmicos com capacidade de reproduzir os níveis de pressão e vazão do sistema cardiovascular humano, com pistões, válvulas, câmaras de complacência, dispositivos para ajustes e medição de pressão e vazão. Este artigo apresenta o desenvolvimento e a avaliação de um fluxômetro eletromagnético (FE). O custo elevado de um fluxômetro por ultrassom (FUS) pode inviabilizar algumas pesquisas com simuladores; desta forma, uma alternativa com menor custo é apresentada neste trabalho. Baseado na indução eletromagnética para medição de vazão em um fluido iônico, o FE desenvolvido mostrou ser uma solução de baixo custo. O transdutor foi montado em um tubo de plástico com diâmetro interno de 9,5 mm, excitado por um campo magnético de 0,35 T, possui 4 eletrodos que, ligados a um circuito eletrônico, fornecem tensão elétrica proporcional à velocidade do fluido. A equação da tensão induzida, técnicas para calibração, ensaios e resultados são apresentados. Para a realização dos ensaios, foram utilizados um simulador cardiovascular e um FUS como referência. Os dados foram obtidos por hardware e software da National Instruments. Dentre os resultados, destaca-se o baixo desvio padrão de 0,043 L/min do FE para uma vazão de 3,56 L/min. O maior erro porcentual relativo foi de 1,49 ± 1,25%. Em um dos gráficos de vazão do FE observou-se um comportamento não monotônico, confirmado por uma análise da resposta em freqüência, observando-se maior amplitude na segunda, terceira e quarta harmônicas. Os resultados indicaram que o FE pode substituir o FUS em aplicações com simuladores hidrodinâmicos.


Implantable devices, prosthesis and their associated surgical techniques in cardiology are constantly under development. Many research groups have been using hydrodynamic simulators as a tool to assist the development in cardiovascular area, capable to mimic pressure and flow found in human cardiovascular system. They are made with plastic tubes, compliances chambers, valves, moving diaphragms and clamps for pressure and flow adjustments. The high cost of ultrasonic flow meters (UF) may difficult, for some research groups, the development of their own mock systems. This paper presents a simple and low cost electromagnetic flow meter (EF) useful for those cardiovascular simulation systems. EF measures flow of ionic fluids based on electromagnetic induction. A special transducer was assembled directly on a plastic tube with 9.5 mm of inner diameter. The transducer has 4 electrodes and, when excited by a magnetic field of 0.35 tesla, detects electric tension that is proportional to the fluid velocity. In this paper, induced electric potential equation, calibration techniques, performance tests and results are presented. A cardiovascular simulation system was used as test setup with an UF (Transonic Systems Inc.) as comparative flow meter. The signals were acquired by a PCI-6036E card and processed with LabView® 7.1 (National Instruments). The results from EF showed a standard deviation (SD) of 0.043 L/min for a flow of 3.56 L/min. The largest relative error was of 1.49 ± 1.25%. In one flow signal from the EF, the non monotonic behavior suggests a rich harmonic signal, which was confirmed by an analysis in the frequency domain. In vitro performance tests indicated that our EF can substitute the commercial available UF for hydrodynamic simulator application.


Subject(s)
Flow Measurements , Flowmeters , Models, Cardiovascular , Computer Simulation , Risk Measurement Equipment , Diagnostic Techniques, Cardiovascular/instrumentation
4.
Rev. Soc. Bras. Clín. Méd ; 6(2): 53-58, mar.-abr. 2008. tab
Article in Portuguese | LILACS | ID: lil-491524

ABSTRACT

Objetivos: Controlando-se a transmissão da doença de Chagas, faz-se necessário investir na prevenção dos agravos de sua cardiopatia crônica. Procurou-se comparar a propedêutica cardiológica acessível na Atenção Primária, com exames mais complexos, na avaliação dos cardiopatas chagásicos. Métodos: Foram analisados os prontuários de 515 pacientes acompanhados no ambulatório do Grupo de Estudos em Doença de Chagas (GEDoCh) - HC / UNICAMP, Campinas,SP, sendo selecionados 52 com registro completo dos exames básicos - avaliação clínica, ECG convencional (ECG) e RX detórax (RX), e ao menos um dos exames complementares: teste de esforço (TE), ecocardiograma (ECO) e eletrocardiografia dinâmica (Holter). Excluíram-se os prontuários com dados incompletos ou de portadores de outras cardiopatias, incluindos edoença arterial coronariana e doença reumática, hipertensão arterial e alcoolismo. Comparamos-se os resultados desses dois tipos de investigação. Resultados: A avaliação clínica, associada ao ECG e RX,mostrou significância quando confrontada com aptidão cardiorrespiratória(ACR) e classe funcional (CF) obtidas no TE(p=0,0062; p=0,0409). Os cardiopatas mais graves apresentaram comprometimento maior da ACR e CF mais baixa, comparando-se aos menos graves. Os demais exames complexos não mostraram associação significativa com a propedêutica cardiológica disponível em nível de Atenção Primária.Conclusão: A propedêutica cardiológica básica permite classificar a cardiopatia chagásica em formas leve ou grave. Entretanto, apenas dois parâmetros obtidos no TE (ACR e CF) mostraram correlação significativa com o exame clínico. De qualquer modo, a propedêutica cardiológica básica é relevantena consideração do nível em que devem ser assistidos os portadores crônicos dessa afecção.(AU)


Objective: The next step after the control of Chagas’ diseasetransmission is the investment in the prevention of the chagasic cardiopathy damage. This study intended to comparethe basic cardiologic investigation with the complex cardiologic investigation in Chagas’ heart disease.Methods: The study evaluated 52 medical records among515 of the chagasic patients from the Ambulatory of the Chagas’Disease Study Group (State University of Campinas, SP). These patients showed complete registration of Clinical Evaluation, ECG, Chest Radiography, and, at least one of the morecomplex exams: Ergometric Test, Echocardiography Evaluation,and Holter. It was excluded those with incomplete data, other cardiac diseases, arterial hypertension, and alcoholism.The results obtained from the two kinds of cardiologic evaluationwere compared. Results: The clinical evaluation plus the ECG and chestradiography showed statistical significance compared withthe cardio - respiratory aptitude (CRA) and the functional class (FC) obtained from the Ergometric Test (p = 0.0062; p= 0.0409). The patients classified in the severe stages of the Chagas’ heart disease presented lesser levels of CRA and FC compared with those in the benign stages. The other complexexams didn’t show significant association with the availableexams usually found in the Primary Health Units. Objective: The next step after the control of Chagas’ diseasetransmission is the investment in the prevention of the chagasic cardiopathy damage. This study intended to comparethe basic cardiologic investigation with the complex cardiologic investigation in Chagas’ heart disease. Methods: The study evaluated 52 medical records among 515 of the chagasic patients from the Ambulatory of the Chagas’Disease Study Group.(AU)


Subject(s)
Humans , Primary Health Care , Chagas Cardiomyopathy/prevention & control , Education, Premedical , X-Rays , Medical Records , Diagnostic Techniques, Cardiovascular/instrumentation , Electrocardiography/instrumentation
6.
J. bras. med ; 76(4): 40-47, abr. 1999. ilus, tab, graf
Article in Portuguese | LILACS | ID: lil-344326

ABSTRACT

Desde sua introdução na prática clínica por Master em meados dos anos 40, o teste de esforço (TE) tem seido utilizado como elemento de diagnóstico da doença obstrutiva coronária, mercê de sua suposta capacidade para identificar lesões em uma, duas ou três artérias, de acordo com o comportamento do segmento ST ao exercício. Todavia, esta concepção sofreu profundas modificações ao longo da última década, passando o TE a ser encarado como um método de avaliação funcional do sistema aeróbico, no qual diversos elementos de análise devem ser apreciados e não apenas o segmento ST do eletrocardiograma de esforço, como tem sido hábito entre os clínicos e cardiologistas menos afeitos ao método. O artigo trata desta importante modificação conceitual e mostra como o TE deve ser interpretado nos dias atuais


Subject(s)
Humans , Diagnostic Techniques, Cardiovascular/instrumentation , Diagnostic Techniques, Cardiovascular/trends , Exercise Test/methods , Exercise Test/trends , Exercise Test , Ergometry